Fluke FLUKE-902 FC (4695814) 902 FC True-RMS HVAC Clamp Meter
The Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 kΩ; AC current and AC/DC voltage; capacitance; and contact temperature, all with just one tool. Plus its small form factor makes it easy to hang on to and navigate in tight work spaces.
Features:
- A wireless Fluke Connect®-enabled clamp meter designed specifically for the needs of HVAC technicians
- Ergonomic design fits in your hand and can be used while wearing personal protective equipment
- Large, easy-to-read backlit display improves readings in low light settings
- Comes with a TPAK magnetic hanging strap, batteries soft carrying case, and three-year warrant
- Offers True-RMS voltage and current measurements to accurately measure non-linear signals
- Offers 200 µA DC current measurements to measure flame rod
- Extends resistance range to measure thermistors up to 60kΩ
- Captures flue gas temperature
- Measures start and run motor capacitors
- Measures variable frequency drive performance
Specifications:
- Function A ac (via Jaw):
- Resolution: 0.01/0.1 A
- Function A ac (via Jaw) Accuracy:
- 2.0% ±5 digit (45-65 Hz)
- 2.5% ±5 digit (65-400 Hz)
- Range: 60.00/600.0 A
- Function A ac (via Jaw) Crest Factor (50Hz or 60Hz):
- 2.5 MIN@220 A
- 3.0 MIN@180 A
- > 1.4 MIN@600 A
- Add 2% for CF>400 A
- Function V ac:
- Resolution: 0.1 V
- Accuracy: 1.5% ±5 digits
- Range: 600.0 V
- Function V dc:
- Resolution: 0.1 V
- Accuracy: 1.5% ±5 digits
- Range: 600.0 V
- Function Ohms:
- Resolution: 0.1/1/10
- Accuracy: 1% ±5 digits
- Range: 600/6000/60.00 kΩ
- Function Capacitance:
- Resolution: 0.1/1 µF
- Accuracy: 1% ±4 digits
- Range: 100.0/1000 µF
- Function µA:
- Resolution: 0.1 µA
- Accuracy: 1% ±5 digits
- Range: 200 µA
- Contact temperature:
- Resolution: 0.1 C/F
- Accuracy: 1% ±8 digits
- Range: -40 to 400 °C (-40 °F to 752 °F)
- Continuity beeper:
- Beeper volume: 75 dBA nom. 15 cm. from case front
- On threshold: <=30 Ω
- Maximum voltage between any terminal and earth ground: 1000 V
- Battery type: 2 AA alkaline batteries, NEDA 15A, IEC LR6
- Operating Temperature: -10 °C to +50 °C (14 °F to +122 °F)
- Storage Temperature: -40 °C to +60 °C (-40 °F to +140 °F)
- Operating humidity:
- Non condensing (< 10 °C [50 °F])
- ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F])
- ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F))
- ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F))
- Operating Altitude: 3,000 m (9,842 ft)
- Storage Altitude: 12,000 m (39,370 ft)
- Safety:
- IEC 61010-1, Pollution Degree 2
- IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
- IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
- IP Rating: IEC 60529: IP30, non-operating
- Radio Frequency Certification: FCC ID:T68-FBLE IC:6627A-FBLE
- Dimensions (L x W x H): 230mm x 83.7mm x 45.4mm
- Weight 0.42kg
Warranty:
- Three Years Warranty Covered By Fluke