Fluke FLUKE-87-5 (2074974) 87V Industrial Digital Multimeter
The Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment even in loud, high-energy, and high-altitude locations. A low pass filter supports accurate frequency measurements on VFDs and captures intermittents as fast 250 µS.
Features:
- Rugged, high accuracy industrial multimeter to measure current, voltage and frequency on complex variable frequency drive (VFD) signals
- Offers true-RMS AC voltage and current for measuring non-linear signals
- Features—6000 counts, 3-3/4 digit resolution, or 20,000 counts, 4-1/2 digit—resolution
- Fits into an optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
- Includes an analog bargraph for fast changing or unstable signals
- Presents a large digit display with bright, two-level backlight for easier reading in low light
- Delivers 0.05% DC accuracy
- Measures up to 1000 VAC and DC
- Provides 10,000 µF capacitance range for components and motor caps
- Captures intermittents as short as 250 µS
- Safety rated CAT III 1000 V, CAT IV 600 V
- Includes a built-in thermometer and temperature probe
Specifications:
- Voltage DC:
- Maximum voltage: 1000 V
- Accuracy: ±(0.05% + 1)
- Maximum resolution: 10 µV
- Voltage AC:
- Maximum voltage: 1000 V
- Accuracy: ±(0.7% + 2) True RMS
- AC bandwidth: 20 kHz with low pass filter; 3 dB @ 1 kHz
- Maximum resolution: 0.1 mV
- Current DC:
- Maximum amps: 10 A (20 A for 30 seconds maximum)
- Amps accuracy: ±(0.2% + 2)
- Maximum resolution: 0.01 µA
- Current AC:
- Maximum amps: 10 A (20 A for 30 seconds maximum)
- Amps accuracy: ±(1.0% + 2) True RMS
- Maximum resolution: 0.1 µA
- Resistance:
- Maximum resistance: 50 MΩ
- Accuracy: ±(0.2% + 1)
- Maximum resolution: 0.1 Ω
- Capacitance:
- Maximum capacitance: 9,999 µF
- Accuracy: ±(1% + 2)
- Maximum resolution: 0.01 nF
- Frequency:
- Maximum frequency: 200 kHz
- Accuracy: ±(0.005% + 1)
- Maximum resolution: 0.01 Hz
- Duty cycle:
- Maximum duty cycle: 99.9%
- Accuracy: ±(0.2% per kHz + 0.1%)
- Maximum resolution: 0.1%
- Temperature measurement (excluding probe):
- –200.0 °C – 1090 °C
- –328.0 °F – 1994.0 °F
- 80 BK temperature probe:
- –40.0 °C – 260 °C
- –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater
- Conductance:
- Maximum conductance: 60.00 nS
- Accuracy: ±(1.0% + 10)
- Maximum resolution: 0.01 nS
- Diode:
- Range: 3 V
- Resolution: 1 mV
- Accuracy: ±(2% + 1)
- Duty cycle range accuracy: Within ±(0.2% per kHz + 0.1%)
- Operating Temperature: –20 °C to + 55 °C
- Storage Temperature: –40 °C to + 60 °C
- Humidity (without condensation):
- 0% – 90% (0 °C – 35 °C)
- 0% – 70% (35 °C – 55 °C)
- Operating Altitude: 2000 m
- Overvoltage category: EN 61010–1 to 1000 V CAT III, 600V CAT IV
- Agency approvals: CE, CSA, RCM
- Display:
- Digital: 6000 counts updates 4/sec. (19,999 counts in high–resolution mode)
- Analog: 32 segments, updates 40/sec
- Frequency: 19,999 counts, updates 3/sec at > 10 Hz
- Battery Life: ~400 hours typical, without backlight
- Shock: 1 Meter drop per IEC 61010–1:2001
- Vibration: Per MIL–PRF–28800 for a Class 2 instrument
- Dimensions (L x W x H): 52mm x 98mm x 201mm
- Weight: 0.355kg
Warranty:
- Limited Lifetime Warranty Covered By Fluke