Features:

  • Connect your meter to your smartphone with Fluke Connect Measurements
  • Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
  • Record results directly to your phone and the Cloud
  • Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
  • Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
  • iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)
  • TPAK magnetic hanging strap (included)
  • Integrated VFD low pass filter for accurate motor drive measurements
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • CAT IV 600 V, CAT III 1000 V safety rating

Specifications:

  • AC Current via Jaw
  • Range: 999.9 A
  • Resolution: 0.1 A
  • Accuracy: 
  • 2% ±5 digits (10 Hz to 100 Hz)
  • 2.5% ±5 digits (100-500 Hz)
  • Crest Factor (50 Hz/60 Hz):
  • 3 @ 500 A
  • 2.5 @ 600 A
  • Add 2% for C.F. >2
  • AC Current via Flexible Current Probe:
  • Range: 2500 A
  • Resolution:
  • 0.1 A (≤ 600 A)
  • 1 A (≤ 2500 A)
  • Accuracy:
  • 3% ±5 digits (5 – 500 Hz)
  • Crest Factor (50/60Hz):
  • 3.0 at 1100 A
  • 2.5 at 1400 A
  • 1.42 at 2500 A
  • Add 2% for C.F. > 2
  • DC current:
  • Range: 600.0 A
  • Resolution: 0.1A
  • Accuracy: 2% ± 5 digits
  • AC voltage:
  • Range: 600.0 V
  • Resolution:
  • 0.1 V (≤600.0 V)
  • 1 V (≤1000 V)
  • Accuracy: 1.5 % ± 5 digits
  • DC voltage:
  • Range: 1000.0 V
  • Resolution:
  • 0.1 V (≤600.0 V)
  • 1 V (≤1000 V)
  • Accuracy: 1.0 % ± 5 digits
  • mV dc:
  • Range: 500.0 mV
  • Resolution: 0.1 mV
  • Accuracy: 1% ±5 digits
  • Frequency via Jaw:
  • Range: 5.0 Hz to 500.0 Hz
  • Resolution: 0.1 Hz
  • Accuracy: 0.5% ±5 digits
  • Trigger level:
  • 5 Hz to 10 Hz, ≥10 A
  • 10 Hz to 100 Hz, ≥5 A
  • 100 Hz to 500 Hz, ≥10 A
  • Frequency via Flexible Current Probe:
  • Range: 5.0 Hz to 500.0 Hz
  • Resolution: 0.1 HzAccuracy 0.5% ±5 digits
  • Trigger level: 
  • 5 Hz to 20 Hz, ≥25 A
  • 20 Hz to 100 Hz, ≥20 A
  • 100 Hz to 500 Hz, ≥25 A
  • Resistance:
  • Range: 400.0 Ω/4000 Ω
  • Accuracy: 1 % ± 5 digits

The Biggest Range Of The Best Brands At The Best Prices