Now there’s one intrinsically safe digital multimeter (DMM) you can use in IIC (gas), in Zone 1 and 2 and IIIC (dust), Zone 21 and 22. Whether you work in petroleum, chemical, or pharmaceutical environments, all the test and troubleshooting power you need is packed into the most rugged intrinsically safe (IS) DMM Fluke has ever built. The Fluke 28 II Ex is also waterproof, dust-proof and drop-proof. You’ll be equipped to handle any situation, inside and outside of hazardous zones, without compromising compliance or measurement performance.

Features:

  • A completely sealed, IP67 rated case
  • Withstands drops up to 10 ft or 3 m (with holster)
  • Dustproof per IEC60529 IP6x
  • Waterproof per IEC60529 IPx7
  • Meets IEC Overvoltage Electrical Safety Standard No. 61010-1:2001
    • Measurement Category III, 1000V, Pollution Degree 2
    • Measurement Category IV, 600V, Pollution Degree 2
  • Reversible holster for added protection of the display when not in use

Specifications:

  • Power: Three AAA batteries (Battery life: 400 hours)
  • Display: LCD, with backlight
  • External protection: Rubber holster
  • DC voltage:
    • Range: 0.1 mV to 1000 V
    • Accuracy:±0.05% + 1
  • AC voltage:
    • Range: 0.1 mV to 1000 V
    • Accuracy: ±0.7% +4
  • DC current:
    • Range: 0.1 μA to 10 A
    • Accuracy: ±0.2% + 4
  • AC current:
    • Range: 0.1 μA to 10 A
    • Accuracy: ±1.0% + 2
  • Resistance: 
    • Range: 0.1 Ω to 50 MΩ
    • Accuracy: ±(0.2% + 1)
  • Conductance:
    • Range: 60.00 nS
    • Accuracy: ±(1.0% + 10)
  • Diode test:
    • Range: 2.0 V
    • Accuracy: ±(2.0% + 1)
  • Duty cycle: 
    • Range: 0.0% to 99.9%
    • Accuracy: Within ±(0.2% per kHz + 0.1%) for rise times <1 µs
  • Capacitance:
    • Range: 10 nF to 9999 μF
    • Accuracy: ±(1.0% + 2)
  • Frequency:
    • Range: 0.5 Hz to 199.99 kHz
    • Accuracy: ±(0.005% + 1)
  • Temperature
    • Range: -200°C to +1090°C (-328°F to +1994°F)
    • Accuracy: ±(1.0% + 10)°C [±(1.0% + 10)°F]
  • Display counts: 6000 counts/19,999 counts in high-resolution mode
  • Peak capture: Record transients up to 250 us
  • Min/Max/Avg recording: Display signals up to approximately 100 ms
  • Dimensions (H x W x L): 63mm x 100mm x 198mm
  • Weight: 0.6kg