Fluke FLUKE-117/APAC (5294292) 600V Electricians Multimeter with Non-Contact Voltage
Designed by electricians and engineered by Fluke, the Fluke 117 is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools. With its integrated non-contact voltage detection, Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage, the Fluke 117 is a great choice for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min/Max/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.
Features:
- VoltAlert built in non contact voltage detector. The sensing circuit is located on the top of the meter above the LCD display
- Measures 10 A (20 A overload for 30-seconds)
- Measures resistance, continuity, frequency, and capacitance
- Provides Min/Max/Average to record signal fluctuations
- Features compact ergonomic design for one-handed operation
- Fits into optional ToolPak magnetic hanger for hands-free operation
- CAT III 600 V safety rated
- A large white LED backlight to improve measurement visibility in poorly lit areas
- VoltAlert technology for fast, go/no go non-contact voltage detection
- AutoVolt and low input impedance modes to provide faster, more accurate readings
Specifications:
- Max Voltage: 600V
- Safety:
- IEC 61010–1: Pollution Degree 2
- IEC 61010-2-033: CAT III 600V
- Display Digital: 6,000 counts, updates 4 per second
- Bar graph: 33 segments, updates 32 per second
- Operating temperature: -10°C to + 50°C
- Storage temperature: -40°C to + 60°C
- Battery type: 9 volt Alkaline, IEC 6LR61
- Battery life: 400 hours typical, without backlight
- DC millivolts:
- Range/resolution: 600.0 mV / 0.1 mV
- Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
- DC volts:
- Range/resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.00 V / 0.1 V
- Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
- Auto volts:
- Range/resolution: 600.0 V / 0.1 V
- Accuracy: 2.0% + 3 (DC, 45 Hz to 500 Hz), 4.0% + 3 (500 Hz to 1 kHz)
- AC millivolts1 True RMS:
- Range/resolution: 600.0 mV / 0.1 mV
- Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
- AC volts1 True RMS:
- Range/resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.0 V / 0.1 V
- Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
- Continuity:
- Range/resolution: 600 Ω / 1 Ω
- Accuracy: Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
- Ohms:
- Range/resolution: 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ, 6.000 MΩ / 0.001 MΩ
- Accuracy: 0.9% + 1
- Range/resolution: 40.00 MΩ / 0.01 MΩ
- Accuracy: 5% + 2
- Diode test:
- Range/resolution: 2.00 V / 0.001 V
- Accuracy: 0.9% + 2
- Capacitance:
- Range/resolution: 1000 nF / 1 nF, 10.00 μF / 0.01 μF, 100.0 μF / 0.1 μF, 9999 μF / 1 μF, 100 μF to 1000 μF
- Accuracy: 1.9% + 2
- Range/resolution: > 1000 μF
- Accuracy: 5% + 20%
- Lo-Z capacitance:
- Range: 1 nF to 500 μF
- Accuracy: 10% + 2 typical
- AC Amps True RMA(45Hz to 500Hz):
- Range/Resolution: 6.000 A / 0.001 A, 10.00 A / 0.01 A
- Accuracy: 1.5% +3 (20 A Continuous overload for 30 seconds Max)
- DC Amps:
- Range/Resolution: 6.000 A / 0.001 A, 10.00 A / 0.01 A
- Accuracy: 1.0% +3 (20 A Continuous overload for 30 seconds Max)
- Hz )V or A Input)^2:
- Range/Resolution: 99.99 Hz / 0.01 Hz, 999.9 Hz / 0.1 Hz, 9.999 kHz / 0.001 Hz, 50 kHz / 0.01 Hz
- Accuracy: 0.1% + 2
- Dimensions (L x W x H): 167mm x 84mm x 46mm
- Weight: 0.55kg