Fluke FLK-393FC-PVLEAD (5337394) Solar Tools Kit with 393 FC Clamp Meter and Solar Test Leads
The 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is designed for technicians who work in dc environments up to 1500 V: solar arrays, wind power, electric railways, data centers battery banks for uninterruptible power supplies. The clamp will measure up to 1500 V dc, 1000 V ac, and up to 999.9 A dc or ac through the clamp jaw. The included iFlex flexible current probe extended ac current measurements up to 2500 amps.
This clamp has a thin jaw, giving you access to cables in crowded combiner boxes. Test leads are designed with your work in mind, and are also rated to CAT III 1500 V
Included:
- Fluke 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex
- Test leads, CAT III 1500 V rated, right angle plugs, with safety caps
- iFlex 18 inch flexible current probe
- TPAK magnetic hanging strap
- Premium carrying case
Features:
- IP54 rated, ideal for work outdoors on solar arrays and wind power systems
- DC power measurement, showing readings in kVA
- Audio Polarity indicator helps prevent accidental miswires
- Visual Continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
- Logging and reporting of test results via Fluke Connect software
- Measure safely: CAT III 1500 V rated clamp meter
- Versatile clamp jaw: Thin jaw for access to cables in crowded combiner boxes, able to clamp around multiple cables
- More functions, automatic safeguards: Work efficiently with dc power measurement, audio polarity and visual continuity
Specifications:
- Maximum voltage between any Terminal and Earth Ground:
- AC: 1000 V
- DC: 1500 V
- Batteries: 2 AA IEC LR6 alkaline
- Display: Dual display with backlight
- Automatic Power Off: 20 minutes
- Accuracy: Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
- Temperature Coefficients: Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
- AC Current: Jaw:
- Range: 999.9 A
- Resolution: 0.1 A
- Accuracy: 2 % + 5 digits (10 Hz to 100 Hz), 2.5 % + 5 digits (100 Hz to 500 Hz)
- Crest Factor (50/60 Hz):2. 5 @600.0 A, 3.0 @500.0 A, 1.42 @999.9 A, Add 2 % for C.F. >2
- AC Current: Flexible Current Probe:
- Range: 999.9 A, 2500 A
- Resolution: (0.1 A (≤999.9 A), 1 A (≤2500 A)
- Accuracy: 3 % RD + 5 digits (10 Hz to 500 Hz)
- Crest Factor (50/60Hz): 2.5 @1400 A, 3.0 @1100 A, 1.42@2500 A, Add 2 % for C.F. >2
- Position Sensitivity:

-
| Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error |
| A | 12.7 mm (0.5 in) | 35.6 mm (1.4 in) | ±0.5 % |
| B | 20.3 mm (0.8 in) | 50.8 mm (2.0 in) | ±1.0 % |
| C | 35.6 mm (1.4 in ) | 63.5 mm (2.5 in) | ±2.0 % |
- Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
- DC Current:
- Range: 999.9 A
- Resolution: 0.1 A
- Accuracy:
- 2 % RD + 5 digits[1]
- [1] When using the ZERO (B) function to compensate for offsets.
- AC Voltage:
- Range: 600.0 V, 1000 V
- Resolution: 0.1 V (≤600.0 V), 1 V (≤1000 V)
- Accuracy: 1 % RD + 5 digits (20 Hz to 500 Hz)
- DC Voltage:
- Range: 600.0 V, 1500 V
- Resolution: 0.1 V (≤600.0 V), 1 V (≤1500 V)
- Accuracy: 1 % RD + 5 digits
- mV dc:
- Range: 500.0 mV
- Resolution: 0.1 mV
- Accuracy: 1 % RD + 5 digits
- Amps Frequency: Jaw
- Range: 5.0 Hz to 500.0 Hz
- Resoltion: 0.1 Hz
- Accuracy: 0.5 % RD + 5 digits
- Trigger Level: 5 Hz to 10 Hz, ≥10 A, 10 Hz to 100 Hz, ≥5 A, 100 Hz to 500 Hz, ≥10 A
- Amps Frequency: Flexible Current Probe:
- Range: 5.0 Hz to 500.0 Hz
- Resolution: 0.1 Hz
- Accuracy: 0.5 % RD + 5 digits
- Trigger Level: 5 Hz to 20 Hz, ≥25 A, 20 Hz to 100 Hz, ≥20 A, 100 Hz to 500 Hz, ≥25 A
- Voltage Frequency:
- Range: 5.0 Hz to 500.0 Hz
- Resolution: 0.1 Hz
- Accuracy: 0.5 % RD + 5 digits
- Trigger Level: 5 Hz to 20 Hz, ≥5 V, 20 Hz to 100 Hz, ≥5 V, 100 Hz to 500 Hz, ≥10 V
- DC Power:
- Range: 600.0 kVA (600.0 V dc range), 1500 kVA (1500 V dc range)
- Resolution: 0.1 kVA, 1 kVA
- Accuracy: 2 % RD + 2.0 kVA, 2 % RD + 20 kVA
- Resistance:
- Range: 600.0 Ω, 6000 Ω, 60.00 kΩ
- Resolution: 0.1 Ω (≤600.0 Ω), 1 Ω (≤6000 Ω), 0.01 kΩ (≤60.00 kΩ)
- Accuracy: 1 % RD + 5 digits
- Capacitance:
- Range: 100.0 μF, 1000 μF
- Resolution: 0.1 μF (≤100.0 μF), 1 μF (≤1000 μF)
- Accuracy: 1 % RD + 5 digits
- Inrush Trigger Level: 5 A
- Mechanical:
- Size (L x W x H): 281 mm x 84 mm x 49 mm
- Weight: 520 g
- Jaw Opening: 34 mm
- Flexible Current Probe: 7.5 mm
- Head to electronics connector: 1.8m
- Environmental:
- Operating Temperature: -10 °C to 50 °C
- Storage Temperature: -40 °C to 60 °C
- Operating Humidity: Non condensing (<10°C), ≤90 % RH (at 10 °C to 30 °C), ≤75 % RH (at 30 °C to 40 °C), ≤45 % RH (at 40 °C to 50 °C)
- Operating Altitude: 2000 m
- Storage Altitude: 12 000 m
- Ingress Protection (IP) Rating: IEC 60529: IP54 non-operating
- Electromagnetic Compatibility (EMC)
- International:
- IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
- Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
- Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
- Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
- Safety:
- General: IEC 61010-1, Pollution Degree 2
- Measurement: IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V, IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
- Wireless Radio:
- Radio frequency certification: FCC ID: T68-FBLE, IC: 6627A-FBLE
- Wireless Radio Frequency Range: 2400 MHz to 2483.5 MHz
- Output Power: <100 mW
- SIMPLIFIED EU DECLARATION OF CONFORMITY:
- Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU
- The full text of the EU declaration is available at the following Internet address: www.fluke.com/en-us/declaration-of-conformity
-
Warranty:
- 3 Year Warranty Covered By Fluke Australia