Fluke

Fluke FLK-393FC-PVLEAD (5337394) Solar Tools Kit with 393 FC Clamp Meter and Solar Test Leads

FREE SHIPPING
Item ID: W208896
Model: FLK-393FC-PVLEAD
Second Model: 5337394
$1823.80
Non-Stock Items Terms & Conditions (Additional charges might apply)
This product does not incur bonus points
Humm
|
Zip Pay
|
Afterpay
Check StockCheck Stock Availability

ShippingDelivery
| FREE Shipping over $99*

Shipping cost and delivery time
Best Prices Guaranteed

Fluke FLK-393FC-PVLEAD (5337394) Solar Tools Kit with 393 FC Clamp Meter and Solar Test Leads

The 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is designed for technicians who work in dc environments up to 1500 V: solar arrays, wind power, electric railways, data centers battery banks for uninterruptible power supplies. The clamp will measure up to 1500 V dc, 1000 V ac, and up to 999.9 A dc or ac through the clamp jaw. The included iFlex flexible current probe extended ac current measurements up to 2500 amps.

This clamp has a thin jaw, giving you access to cables in crowded combiner boxes. Test leads are designed with your work in mind, and are also rated to CAT III 1500 V

Included:

  • Fluke 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex
  • Test leads, CAT III 1500 V rated, right angle plugs, with safety caps
  • iFlex 18 inch flexible current probe
  • TPAK magnetic hanging strap
  • Premium carrying case

Features:

  • IP54 rated, ideal for work outdoors on solar arrays and wind power systems
  • DC power measurement, showing readings in kVA
  • Audio Polarity indicator helps prevent accidental miswires
  • Visual Continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
  • Logging and reporting of test results via Fluke Connect software
  • Measure safely: CAT III 1500 V rated clamp meter
  • Versatile clamp jaw: Thin jaw for access to cables in crowded combiner boxes, able to clamp around multiple cables
  • More functions, automatic safeguards: Work efficiently with dc power measurement, audio polarity and visual continuity

Specifications:

  • Maximum voltage between any Terminal and Earth Ground:
    • AC: 1000 V
    • DC: 1500 V
    • Batteries: 2 AA IEC LR6 alkaline
    • Display: Dual display with backlight
    • Automatic Power Off: 20 minutes
  • Accuracy: Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
  • Temperature Coefficients: Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
  • AC Current: Jaw:
    • Range: 999.9 A
    • Resolution: 0.1 A
    • Accuracy: 2 % + 5 digits (10 Hz to 100 Hz), 2.5 % + 5 digits (100 Hz to 500 Hz)
    • Crest Factor (50/60 Hz):2. 5 @600.0 A, 3.0 @500.0 A, 1.42 @999.9 A, Add 2 % for C.F. >2
  • AC Current: Flexible Current Probe:
    • Range: 999.9 A, 2500 A
    • Resolution: (0.1 A (≤999.9 A), 1 A (≤2500 A)
    • Accuracy: 3 % RD + 5 digits (10 Hz to 500 Hz)
    • Crest Factor (50/60Hz): 2.5 @1400 A, 3.0 @1100 A, 1.42@2500 A, Add 2 % for C.F. >2
  • Position Sensitivity:NEC symbol
  • Distance from Optimumi2500-10 Flexi2500-18 FlexError
    A12.7 mm (0.5 in)35.6 mm (1.4 in)±0.5 %
    B20.3 mm (0.8 in)50.8 mm (2.0 in)±1.0 %
    C35.6 mm (1.4 in )63.5 mm (2.5 in)±2.0 %
  • Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
  • DC Current:
    • Range: 999.9 A
    • Resolution: 0.1 A
    • Accuracy:
      • 2 % RD + 5 digits[1] 
      • [1] When using the ZERO (B) function to compensate for offsets.
  • AC Voltage:
    • Range: 600.0 V, 1000 V
    • Resolution: 0.1 V (≤600.0 V), 1 V (≤1000 V)
    • Accuracy: 1 % RD + 5 digits (20 Hz to 500 Hz)
  • DC Voltage:
    • Range: 600.0 V, 1500 V
    • Resolution: 0.1 V (≤600.0 V),  1 V (≤1500 V)
    • Accuracy: 1 % RD + 5 digits
  • mV dc: 
    • Range: 500.0 mV
    • Resolution: 0.1 mV
    • Accuracy: 1 % RD + 5 digits
  • Amps Frequency: Jaw
    • Range: 5.0 Hz to 500.0 Hz
    • Resoltion: 0.1 Hz
    • Accuracy: 0.5 % RD + 5 digits
    • Trigger Level: 5 Hz to 10 Hz, ≥10 A, 10 Hz to 100 Hz, ≥5 A, 100 Hz to 500 Hz, ≥10 A
  • Amps Frequency: Flexible Current Probe:
    • Range: 5.0 Hz to 500.0 Hz
    • Resolution: 0.1 Hz
    • Accuracy: 0.5 % RD + 5 digits
    • Trigger Level: 5 Hz to 20 Hz, ≥25 A, 20 Hz to 100 Hz, ≥20 A, 100 Hz to 500 Hz, ≥25 A
  • Voltage Frequency:
    • Range: 5.0 Hz to 500.0 Hz
    • Resolution: 0.1 Hz
    • Accuracy: 0.5 % RD + 5 digits
    • Trigger Level: 5 Hz to 20 Hz, ≥5 V, 20 Hz to 100 Hz, ≥5 V, 100 Hz to 500 Hz, ≥10 V
  • DC Power:
    • Range: 600.0 kVA (600.0 V dc range), 1500 kVA (1500 V dc range)
    • Resolution: 0.1 kVA, 1 kVA
    • Accuracy: 2 % RD + 2.0 kVA, 2 % RD + 20 kVA
  • Resistance:
    • Range: 600.0 Ω, 6000 Ω, 60.00 kΩ
    • Resolution: 0.1 Ω (≤600.0 Ω), 1 Ω (≤6000 Ω), 0.01 kΩ (≤60.00 kΩ)
    • Accuracy: 1 % RD + 5 digits
  • Capacitance:
    • Range: 100.0 μF, 1000 μF
    • Resolution: 0.1 μF (≤100.0 μF), 1 μF (≤1000 μF)
    • Accuracy: 1 % RD + 5 digits
    • Inrush Trigger Level: 5 A
  • Mechanical:
    • Size (L x W x H): 281 mm x 84 mm x 49 mm
    • Weight: 520 g
    • Jaw Opening: 34 mm
    • Flexible Current Probe: 7.5 mm
    • Head to electronics connector: 1.8m
  • Environmental:
    • Operating Temperature: -10 °C to 50 °C
    • Storage Temperature: -40 °C to 60 °C
    • Operating Humidity: Non condensing (<10°C), ≤90 % RH (at 10 °C to 30 °C), ≤75 % RH (at 30 °C to 40 °C), ≤45 % RH (at 40 °C to 50 °C)
    • Operating Altitude: 2000 m
    • Storage Altitude: 12 000 m
    • Ingress Protection (IP) Rating: IEC 60529: IP54 non-operating
  • Electromagnetic Compatibility (EMC)
  • International:
    • IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
    • Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
    • Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
    • Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
  • Safety:
    • General: IEC 61010-1, Pollution Degree 2
    • Measurement: IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V, IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
  • Wireless Radio:
    • Radio frequency certification: FCC ID: T68-FBLE, IC: 6627A-FBLE
    • Wireless Radio Frequency Range: 2400 MHz to 2483.5 MHz
    • Output Power: <100 mW
  • SIMPLIFIED EU DECLARATION OF CONFORMITY:
    • Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU
    • The full text of the EU declaration is available at the following Internet address: www.fluke.com/en-us/declaration-of-conformity
  • Warranty:

    • 3 Year Warranty Covered By Fluke Australia

The Biggest Range Of The Best Brands At The Best Prices