Fluke FLK-3000 FC IND (4465599) 3000 FC Industrial System
De-energize the cabinet, connect the remote modules, close the cabinet and reenergize. The FC Wireless Industrial System displays the readings wirelessly on the 3000 FC Wireless Digital Multimeter. Connect the three FC Wireless iFlex AC Current Module to your test points, and view the results from all three phases in 1/3 the time and cost of current test methods or connect the FC Wireless AC Voltage Module and view both voltage and current measurements simultaneously. You’ll get better answers, faster, and spend less time in full PPE. From short distances, you can even view readings from modules through closed electrical panels. Plus the Fluke Connect® remote modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.
Features:
- The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement troubleshooting:
- AC and DC voltage measurements to 1000 V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX recording
- CAT III 1000 V, Cat IV 600 V; IP54
- The Fluke v3000 FC Wireless AC Voltage Module offers:
- Measurements up to 1000 V true-RMS AC
- Use as a standalone meter or as part of the system
- A logging function for recording and saving up to 65,000 readings
- The Fluke a3001 FC Wireless iFlex® AC Current Module allow you to measure around awkward sized conductors or get into tight spaces and makes wire access easier:
- Measure up to 2500 A AC
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to 65,000 readings
- Inrush function
Fluke 3000 FC Series Wireless Multimeter
Specifications:
- AC Voltage Range / Resolution:
- 600.0 mV / 0.1 mV
- 6.000 V / 0.001 V
- 60.00 V / 0.01 V
- 600.0 V / 0.1 V
- 1000 V / 1 V
- AC Voltage Accuracy:
- 45 Hz to 500 Hz 1.0% + 3
- 500 Hz to 1 kHz 2.0% + 3
- mV Range / Resolution: 600.0 mV / 0.1 mV
- mV Accuracy: 0.09% + 2
- V Range / Resolution:
- 6.000 V / 0.001 V
- 60.00 V / 0.01 V
- 600.0 V / 0.1 V
- 1000 V / 1 V
- V Accuracy:
- 0.09% + 2
- 0.15% + 2
- ))) Range / Resolution: 600 Ω / 1 Ω
- ))) Accuracy: Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
- Ω Range / Resolution:
- 600.0 Ω / 0.1 Ω
- 6.000 kΩ / 0.001 kΩ
- 60.00 kΩ / 0.01 kΩ
- 60.00 kΩ / 0.1 kΩ
- 600.0 kΩ / 0.001 MΩ
- 50.00 MΩ / 0.01 MΩ
- Ω Accuracy:
- 0.5% + 2
- 0.5% + 1
- 1.5% + 3
- Diode test Range / Resolution: 2.000 V / 0.001 V
- Diode test Accuracy: 1% + 2
- µF Range / Resolution:
- 1000 nF / 1 nF
- 10.00 μF / 0.01 μF
- 100.0 μF / 0.1 μF
- 9999 μF1 / 1 μF
- µF Accuracy:
- 1.2% + 2
- 10% typical
- mA AC (45 Hz to 1 kHz) Range / Resolution:
- 60.00 mA / 0.01 mA
- 400.0 mA 3/ 0.1 mA
- mA AC (45 Hz to 1 kHz) Accuracy: 1.5% + 3
- mA DC Range / Resolution:
- 60.00 mA / 0.01 mA
- 400.0 mA 3/ 0.1 mA
- mA DC Accuracy: 0.5% + 3
- Frequency Range / Resolution:
- 99.99 Hz / 0.01 Hz
- 999.9 Hz / 0.1 Hz
- 9.999 kHz / 0.001 kHz
- 99.99 kHz / 0.01 kHz
- Frequency Accuracy: 0.1% + 1
- mA Function Overload protection: Fused, 44/100 A, 1000 V FAST Fuse
- mA Function Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
- MIN/MAX Recording Accuracy DC functions: The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
- MIN/MAX Recording Accuracy AC functions: The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
- Maximum voltage between any terminal and earth ground: 1000 V DC or AC RMS
- Ω fuse protection from A inputs:0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
- Display (LCD):Update rate: 4/sec
- Volts, amps, ohms: 6000 counts
- Frequency: 10,000 counts
- Capacitance: 1,000 counts
- Battery type: 3 x AA Alkaline batteries, NEDA 15A IEC LR6
- Battery life: 250 hours minimum
- RF communications: 2.4 GHZ ISM Band
- RF communication range:
- Open air, unobstructed: Up to 20m
- Obstructed, sheetrock wall: Up to 6.5m
- Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
- Operating Temperature: -10°C to 50°C
- Storage Temperature: -40°C to 60°C
- Temperature coefficient: 0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
- Relative humidity:
- 0% to 90% (0°C to 35°C)
- 0% to 75% (35°C to 40°C)
- 0% to 45% (40°C to 50°C)
- Operating Altitude: 2,000 m
- Storage Altitude: 12,000 m
- Electromagnetic compatibility - EMI, RFI, EMC, RF
- EN 61326–1:2006, EN 61326–2–2:2006
- ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
- V1.8.1:2008
- FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
- FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
- Safety compliance:
- ANSI / ISA 61010–1 / (82.02.01): 3rd edition
- CAN / CSA-C22.2 No 61010-1-12: 3rd edition
- UL 61010–1: 3rd edition
- IEC / EN 61010–1:2010
- Certifications: CSA, FCC, CE
- Ingress Protection (IP) rating: IP54
- Pollution Degree: 2
- Dimensions (L x W x H): 207mm x 93mm x 47.5mm
- Weight: 0.34kg
Warranty:
- 3 Years Warranty Covered By Fluke
Fluke a3001 FC Wireless iFlex AC Current Module
Specifications:
- Range: 0.5 A to 2500 A AC
- Resolution: 0.1 A
- Accuracy: 3% ±5 digits (5 Hz to 500 Hz)
- Crest factor (50 Hz / 60 Hz):
- 3.0 at 1100 A
- 2.5 at 1400 A
- 1.42 at 2500 A
- add 2% for C.F. > 2
- LCD w/ backlight: 3½ digits
- Log rate/interval: 1 sec minimum/adjustable by PC or front panel
- Battery type: 2 x AA, NEDA 15 A, IEC LR6
- Battery life: 400 hours
- Memory: Record up to 65,000 readings
- RF communications: 2.4 GHZ ISM Band
- RF communication range:
- Open air, unobstructed: Up to 20 m
- Obstructed, sheetrock wall: Up to 6.5 m
- Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
- Operating temperature: -10°C to +50°C
- Storage temperature: -40°C to +60°C
- Temperature coefficient: Add 0.1 x (specified accuracy) /°C (< 18°C or > 28°C)
- Operating humidity:
- 90% at 35°C
- 75% at 40°C
- 45% at 50°C
- Operating Altitude: 2,000 m
- Storage Altitude: 12,000 m
- EMC: EN 61326-1:2006
- Safety compliance: IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
- Safety rating: CAT IV 600 V, CAT III 1000 V
- Certifications: CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
- Ingress Protection (IP) rating: IP42
- Pollution Degree: 2
- Jaw opening: 25.4 cm (10 in) coil
- Dimensions (L x W x H): 14mm x 63.5mm x 165mm
- Weight: 0.22kg
Warranty:
- 3 Years Warranty Covered By Fluke
Fluke v3000 FC Wireless AC Voltage Module
Specifications:
- Range / Resolution:
- 6.000 V / 0.001 V
- 60.00 V / 0.01 V
- 600.0 V / 0.1 V
- 1000 V / 1 V
- Accuracy:
- 45 Hz to 500 Hz1.0% + 3
- 500 Hz to 1 kHz2.0% + 3
- LCD w/ backlight: 3½ digits, 6000 counts, updates 4/sec
- Battery type: 2 x AA, NEDA 15 A, IEC LR6
- Battery life: 400 Hours
- Memory: Record up to 65000 readings
- RF communications: 2.4 GHZ ISM Band
- RF communication range:
- Open air, unobstructed: Up to 20 m
- Obstructed, sheetrock wall: Up to 6.5 m
- Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
- Operating temperature: -10°C to +50°C
- Storage temperature: -40°C to +60°C
- Temperature coefficient: 0.1 x (specified accuracy)/ °C (< 18°C or > 28°C)
- Operating humidity: 90% at 35°C, 45% at 40°C, 45% at 50°C
- Operating Altitude: 2,000 m
- Storage Altitude: 12,000 m
- EMC: EN 61326-1:2006
- Safety compliance:
- ANSI/ISA 61010-1 / (82.02.01) 3rd edition
- CAN/CSA-C22.2 No 61010-1-12 3rd edition
- UL 61010-1 3rd edition
- IEC/EN 61010-1 2010
- Safety rating: CAT IV 600 V, CAT III 1000 V
- Certifications: CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
- Ingress Protection (IP) rating: IP42
- Pollution Degree: 2
- Dimensions (L x W x H): 14mm x 63.5mm x 165mm
- Weight: 0.22kg
Warranty:
- 3 Years Warranty Covered By Fluke